DuPont™ Styrofoam™ Brand Roofmate™ XPS Insulation

Water-Resistant Insulation for Protected Membrane Roofing Systems

styrofoam-brand-roofmate-product-logo-image1.jpg
styrofoam-brand-roofmate-product-logo-image2.jpg
styrofoam-brand-roofmate-product-logo-image3.jpg
styrofoam-brand-roofmate-product-logo-image4.jpg

DuPont™ Styrofoam™ Brand Roofmate™ XPS Insulation

Water-Resistant Insulation for Protected Membrane Roofing Systems

<br><b>DuPont™ Styrofoam™ Brand Roofmate™ Extruded Polystyrene (XPS) Insulation</b> is designed for installation above waterproofing or roofing membranes in protected membrane roof (PMR) or green roof applications. <br><br> Engineered for use on heavyweight decks (e.g. reinforced concrete) with a ballast layer or gravel or concrete slabs, <b>Styrofoam™ Brand Roofmate™ XPS Insulation</b> helps the roof membrane maintain a steady temperature, minimizing the harmful effects of freeze thaw cycles, weathering and physical damage during and after construction.
 
 
 
 
 
 

Features & Benefits 

 
 
 
 
 
 

Specifications

 
 
 

Standard Sizes

Thickness Width Length R-Value Edge Treatment
1.0 in. 2 ft. 8 ft. 5.0 Butt Edge
2.0 in. 2 ft. 4 ft. 10.0 2-sided Shiplap
2.0 in. 2 ft. 8 ft. 10.0 4-sided Shiplap
3.0 in. 2 ft. 4 ft. 15.0 2-sided Shiplap
3.0 in. 2 ft. 8 ft. 15.0 4-Sided Shiplap
4.0 in. 2 ft. 4 ft. 20.0 2-sided Shiplap
4.0 in. 2 ft. 8 ft. 20.0 4-Sided Shiplap

Note: Please be advised that additional sizes may be available. Availability of all sizes varies by region and is subject to change. For further information, please contact your local DuPont Sales Representative or call us at 1-866-338-7668.

 
 
 

Testing

<b>Styrofoam™ Brand Roofmate™ XPS Insulation</b> exhibits physical properties as indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.

TEST METHOD TEST TITLE PROPERTY RESULTS
FIRE
CAN/ULC-S102.2 Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies Surface Burning Characteristics Flame Spread - 295
Smoke Developed - 635
THERMAL
CAN/ULC-S770 Standard Test Method for Determination of Long-Term Thermal Resistance of Closed-Cell Thermal Insulating Foams Long-Term Thermal Resistance @ 23.8 °C (75°F) mean temp1 1.71 m2·°C/W
ASTM C5182 Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus Thermal Resistance per inch, @ 75°F mean temp. 5.0 ft2•h•°F/Btu, R-value
min. (0.88 RSI)
ASTM D696 Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between −30°C and + 30°C with a Vitreous Silica Dilatometer Coefficient of Linear Thermal Expansion 6.3 x 10-2mm/m• °C
(3.5 x 10-5 in/in•°F)
ASTM D2126 Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging Change in Dimensions 1.5 % linear change, max.
STRENGTH
ASTM D1621 Standard Test Method for Compressive Properties of Rigid Cellular Plastics Compressive Strength4 241 kPa (35 psi) , min.
ASTM C203 Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation Flexural Strength 352 kPa (51 psi), min.
WATER
ASTM D2842 D2842-Test Method for Water Absorption of Rigid Cellular Plastics Water Absorption 0.7 % by volume, max.
ASTM E96 Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials Water Vapor Permeance5 50 ng/Pa•s•m2 (0.87 perm), max.

1Long-term predicted thermal resistance value for 50 mm thickness.

2Thermal values are consistent with the criteria of ASTM C578 and are not assessed by the CCMC. Depending on the product, a 15-, 30- or 50- year limited thermal warranty is available.

4Vertical compressive strength is measured at 10 percent deformation or at yield, whichever occurs first. Since Styrofoam™ Brand Extruded Polystyrene Foam Insulations are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep and fatigue deformation. For static loads, 3:1 is suggested. For dynamic loads, 5:1 is suggested.

5Water vapor permeance varies with product type and thickness. Values are based on the desiccant method, and they apply to insulation 25.4 mm (1.0-inch) in thickness. Thicker products have lower permeance.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FAQ

What are the types for DuPont™ Styrofoam™ Brand Extruded Polystyrene Foam Insulation products based on CAN/ULC S701?
Styrofoam™ Brand Extruded Polystyrene (XPS) Insulation products available in Canada fit into the following types:

Type 2 Styrofoam™ Brand Panelmate™ XPS Insulation

Type 3 Styrofoam™ Brand Cavitymate™ XPS Insulation Styrofoam™ Brand Cavitymate™ Ultra XPS Insulation Styrofoam™ Brand Cladmate™ CM20 XPS Insulation Styrofoam™ Brand Panelmate™ XPS Insulation

Type 4 Styrofoam™ Brand SM XPS Insulation Styrofoam™ Brand Roofmate™ XPS Insulation Styrofoam™ Brand Highload 40 XPS Insulation Styrofoam™ Brand Highload 60 XPS Insulation Styrofoam™ Brand Highload 100 XPS Insulation

Where can I buy Styrofoam™ CT and Roofmate™ CT?
The products formerly known as Styrofoam™ CT and Roofmate™ CT are currently manufactured and marketed by Tech-Crete Processors Ltd. under new trade names. Roofmate™ CT is now marketed as CTI™ Roof Panel (also available with a white concrete topping - trade name SRI™ Roof Panel), and Styrofoam™ CT is now marketed as CFI™ Wall Panel. CTI™ and SRI™ Roof Panels are light weight, self-ballasted insulated panels intended for Protected Membrane Roof assemblies produced with highly efficient Styrofoam™ brand insulation and a durable concrete topped surface. CFI™ Wall Panels are insulated panels intended for use below, and above grade, against masonry, providing STYROFOAM™ brand insulation and a durable concrete facing in a one step installation.

Contact Tech-Crete Processors Ltd 250-832-9705 Tech-Crete

What are the ASTM C578 classifications for DuPont™ Styrofoam™ Brand Extruded Polystyrene Foam Insulation products?
The ASTM C578 classifications for DuPont™ Styrofoam™ Brand Extruded Polystyrene (XPS) Insulation products are as shown below:
ASTM C578 Types DuPont Products
Type X

Styrofoam™ Brand Residential Sheathing Styrofoam™ Brand Cavitymate™ XPS Insulation Styrofoam™ Brand Panel Core 20

Type IV

Styrofoam™ Brand Tongue and Groove Insulation Styrofoam™ Brand Square Edge XPS Insulation Styrofoam™ Brand Scoreboard XPS Insulation Styrofoam™ Brand Deckmate™ Plus XPS Insulation Styrofoam™ Brand Deckmate™ Plus FA XPS Insulation Styrofoam™ Brand Cavitymate™ Plus XPS Insulation Styrofoam™ Brand Cavitymate™ Ultra XPS Insulation Styrofoam™ Brand Panel Core 30 Freezermate™ XPSInsulation Styrofoam™ Brand Ag BoardXPS Insulation

Type VI

Styrofoam™ Brand Highload 40 XPS Insulation Styrofoam™ Brand Panel Core 40 XPS Insulation Styrofoam™ Brand Roofmate™ XPS Insulation

Type VII

Styrofoam™ Brand Highload 60 XPS Insulation Styrofoam™ Brand Plazamate™ XPS Insulation

Type V

Styrofoam™ Brand Highload 100 XPS Insulation

What are the ballast requirements for perimeter areas or penetrations in Protected Membrane Roof (PMR) assemblies?
Certain areas of the protected membrane roof (PMR) insulation require additional ballast to overcome high wind loads and to restrain the foam from floating during heavy rain storms. This ensures that individual stones cannot migrate to below the foam and abrade the membrane. Areas needing such additional ballasting are:

Perimeter Edge of Insulation: which is an 8-foot-wide swath running along the perimeter edge of the roof insulation (and which includes any insulation adjacent to higher walls).

Penetrations Through Insulation: which are four-foot-wide swaths running around any roof insulation penetrations which exceed 4 feet in any direction, such as skylights, expansion joints, equipment pads, etc.

Corners: where arrays of concrete pavers are required in higher wind zones or with low parapet walls. These requirements are consistent with both the ANSI/SPRI RP-4 Ballast Design Guide (the procedure required by the International Building Code) and Factory Mutual requirements (Factory Mutual Property Loss Prevention Data Sheet 1-29 Page 18).

For more information, download Tech Solutions 508.3: Ballast Design Guide for PMR Systems (43-d100241). Call 1-833-338-7668 for ballast design information in Canada

 
 
 
 
 
 