DuPont™ Tyvek® HomeWrap®

Sturdy Housewrap Engineered for Energy Efficiency

tyvek-homewrap-product-logo-image1.jpg
tyvek-homewrap-product-logo-image2.jpg
tyvek-homewrap-product-logo-image3.jpg
tyvek-homewrap-product-logo-image4.jpg

DuPont™ Tyvek® HomeWrap®

Sturdy Housewrap Engineered for Energy Efficiency

<br><b>DuPont™ Tyvek® HomeWrap®</b> is the original house wrap, leveraging advanced material science to keep air and water out while allowing water vapour to escape. This contributes to enhanced building durability by protecting homes from damaging wind and rain that can penetrate exterior cladding. <br><br> <b>Tyvek® HomeWrap®</b> is uniquely engineered by spinning extremely fine high-density polyethylene (HDPE) fibers that are fused together to form a strong, uniform web. This robust structure creates millions of tiny pores that resist bulk water and air penetration while allowing moisture vapor to pass through. <br><br> Additionally, <b>Tyvek® HomeWrap®</b> can reduce home energy bills by controlling air flow and water intrusion, thereby improving insulation performance and HVAC efficiency. It is designed to keep homes cool in the summer, warm in the winter, and dry all year round.
 
 
 
 
 
 

Features & Benefits 

 
 
 
 
 
 

Specifications

 
 
 

Standard Sizes

Unit Width Length
Roll 18 in. 100 ft.
Roll 3 ft. 100 ft.
Roll 5 ft. 200 ft.
Roll 9 ft. 100 ft.
Roll 9 ft. 150 ft.
Roll 9.50 ft. 100 ft.
Roll 10 ft. 100 ft.
Roll 10 ft. 150 ft.
 
 
 

Testing

<b>Tyvek® HomeWrap™</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact your local DuPont™ Tyvek Specialist before writing specifications around this product. Product properties are as follows:

TEST METHOD TEST TITLE PROPERTY RESULTS
AIR
ASTM E1677 Standard Specification for Air Barrier (AB) Material or Assemblies for Low-Rise Framed Building Walls Air Penetration Resistance Type 1
ASTM E2178 Standard Test Method for Determining Air Leakage Rate and Calculation of Air Permeance of Building Materials Air Penetration Resistance .01 L/S/m2@75 Pa
TAPPI T460 Air resistance of paper (Gurley method) Air Penetration Resistance 1080 sec/100cc
STRENGTH
ASTM D882 Standard Test Method for Tensile Properties of Thin Plastic Sheeting Breaking Strength 30/30
lbs/in
TAPPI T-410 Grammage of Paper and Paperboard (Weight per Unit Area) Basis Weight 1.8 oz/yd2
WATER
ASTM E2273 Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies Drainage Efficiency ICC-ES AC 24 Section 6.11 ICC-ES AC 235 Section 4.5 >90%
Pass
Pass
ASTM E96 Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials Water Vapor Transmission Method B 1720 ng/Pa•S•m2
30 perms
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 